Date : 15th-March-2010 06:09 AM
Thread Title : Engine does not stop when mags are off
Several times when trying to turn off the engine for soaring, the engine does not stop (occurs occasionally also on the ground) when turning the mags off. The only way to stop the engine then is to starve it by turning the fuel selector off.
Has anybody else experienced this? I am worried that this may an indication of a bigger problem.
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Date : 16th-March-2010 11:55 PM
My maintenance manual has the following laminate schedule:
Ref Fibers Weight per sq.yd (oz/sq.yd)
Manufacturer: Interglass (Germany)
Foam - Klegecel ref. 55 or Conticell 60 thickness 0.12, 0.18, 0.24, or 0.45
Gel Coat - Geal Coat Ref. 03-69066 (white)
Hardener - 07-20500 (10% by weight)
Manufacturer - Lesonal - AKSO (Germany)
(I'd use urethane for the top coat paint and primer in favor of gel coat and epoxy primer. We like De Beers Berocryl Series 400)
Primer Epoxy ref. 005.024.861 / 004.400.862 (white)
PU ref. 001.021.826/001.400.826
Manufacturer: Tecnoquimica (Brazil)
inner 2 layers tissue ref. 92145
- Foam Klegecell 55 or Conticell 60 .0315" (8mm) thickness
outer 2 layers tissue ref 92145
- Foam Klegecell 55 or Conticell 60 0.24" (6mm) thickness
Foam Klegecell 55 or Conticell 60 0.315" (8mm) thickness
1 layer tissue ref. 92125 (except vertical stabilizer)
1 layer tissue ref. 92125 (except vertical stabilizer)
1 layer tissue ref. 92110 (only vertical stabilizer)
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Date : 17th-March-2010 12:02 AM
Thread Title : Mag switch problem
Try testing your mag switches individually with a continuity meter and make sure the switch is functioning properly. It sounds like you may have one of your mag switches going bad, causing intermittent contact and not grounding the ignition modules (mags) when you switch it off. This would allow the engine to continue to run on one ignition circuit. I doubt that both switches are bad, probably just one.
I've seen this sort of toggle switch failure happen before on another airplane (not a Ximango).
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Date : 20th-March-2010 06:44 PM
It is possibly one of the electronic mag units (A+B) situated on top of the engine - I had that - stopped the engine by semi feathering - UK cost new was about $700
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
Date : 21st-March-2010 02:57 PM
Wow, hadn't heard that. I'd heard the ignition modules either work or they don't. Hmmm. An intermittent black box. That would certainly add some mystery, wouldn't it?
A broken wire in the ignition circuit could cause an intermittent problem like Hermann describes, too. That's certainly possible the way these Rotax beasties shake when they start up and shut down.
Thanks for posting your experience!
-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-